“ϊ–{‰Όέƒz[ƒ€ƒy[ƒW

nihonkasetsu corporation

HOME
>
K-B JOINT
>
Hydraulic Pressure Test

KB JOINT

NETIS Registration NoFHK-040003

Hydraulic Pressure Test (TYPE-A)

Hydraulic pressure resistance tests have been conducted at Hokkaido Concrete Technical Center and its performance has been approved.

‘Test Sample Overview

Size
Inducing Joint Unit
Number of units
Product name
Type
Size
ƒ³5.91x9.84
iinchj
K-B Joint
Waterproof type
H70
0.98~2.76~3.94
2units
H50
0.98~1.97~3.94
Test Sample Overview

‘Test Method

ŽŽŒ±•ϋ–@Test Method
Test Method
Water pressure has been exercised on the pressurized side (A) in the order of pressure level, 0.05, 0.1, 0.15, 0.2, 0.25, 0.3, 0.35, 0.4, 0.45, and 0.5Mpa. Water pressure has been applied for 15 minutes at each pressure level and occurrence of water leakage has been checked at the observed side (B).

‘Test Result

Water pressure (Mpa)
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
Pressurized time (min.)
15
15
15
15
15
15
15
15
15
15
KB joint waterproof Type70
›
›
›
›
›
›
›
›
›
›
KB joint waterproof Type5
›
›
›
›
›
›
›
›
›
›
›-mark indicates that there was no water leakage.